Product number ET603 Product name: temperature measuring and disinfection machine Product size: 180*75*100mm Material: ABS+PP Water tank capacity :350ML Temperature measurement range :32-42.9℃ Spray induction distance: 0-3cm Temperature measurement range: 0-4cm Ejection time: 0.25s Standby current :3mA Net weight :222G Gross weight :275G Scope of application: school, hospital, office area, etc. Function Description Switch on and off: press A button to turn on the machine, long press A button to turn off the machine. Parameter setting: Long press the B key to enter the setting mode.A key toggle setting object F1, F2, F3 in setting mode: F1: Set alarm temperature (default 38.0), B key -,C key +. F2: Set error compensation (default 0.0), B key -,C key +.F3: Set the temperature measurement prompt tone "Default ON",B key C key toggle. After setting F3, press "A" button again to save and automatically shut down. It will take effect after starting up. |